46 SERIES
SINGLE OR DOUBLE-CHANNEL CONTROL UNIT
In advanced, high-end water treatment applications, professionals choose 46 Series controllers to benefit from exceptional ease of use and full programming autonomy within their process.
With a graphic display showing digital output status, washing cycle and alarms plus intuitive controls for instrument calibration and configuration, it’s never been easier to take control.
FEATURES
- IP65-rated ABS wall-mounted casing
- Two independent 4-20mA output with galvanic isolation
- Four independent relays, two set-points, remote alarm and backwashing sensor setting by software
- On/Off, timed and proportional (PWM) routine function setting
- Solid state relay (SSR) with Wi-Fi embedded module, two-frequency output signal and two set-points
MEASURES
- pH / ORP
- Conductivity
- Chlorine
- Chlorine dioxide
- Ozone
- Hydrogen peroxide
- Peracetic acid
- Chlorites
- Bromine
- Dissolved Oxygen
- Turbidity
- Suspended Solids
- Flow
APPLICATIONS
- Wastewater
- Drinking water
- Fish farming
- Electroplating
- Clean in place
- Food and beverage
- Pulp and paper
TECHNICAL SPECIFICATION
Feature | DESCRIPTION |
---|---|
Power Supply (100...240 VAC) | From 100 to 240 VAC ±10%, 8 W |
Frequency | 50 to 60 Hz |
Power Supply Fuse | Fuse glass body 5x20 mm T1.25AL250V |
Short Circuit Protection | Active |
Power Supply (24...48 VDC) | From 24 to 48 Vdc, or 24Vac ±20%, 8 W |
Reverse Polarity Protection | Active |
Relay Outputs | RL1, RL2, RL3, and RL4: 2-SPST mechanical 250 VAC/5A, 30 VCC/3 A |
Relay RL1, RL2 Configuration | Load activation |
Relay RL3, RL4 Configuration | Load activation, probe wash, alarm repetition |
Cycle Time | 1 sec to 3600 sec |
Delay Time | 1 sec to 3600 sec |
Test Mode | ON, OFF |
SSR Outputs | SSR1 and SSR2: 2-SPST 60 V, max 100 mA, Bidirectional, NPN, PNP |
Resistance in ON State | 5 ohm max |
Leakage Current in OFF State | 1 uA max |
SSR Configuration | Pulse output |
Frequency Range | 0 to 400 pulse/min |
Pulse Duration | 100 m/sec |
Analogue Output Signals | 2 outputs 4-20 mA, galvanically isolated from one another and from the power supply |
Measure Error | ± 0.01 mA |
Load Max. | 800 Ω |
Error Condition | NAMUR Alarm: OFF, 3.6 mA, 22 mA |
Digital Inputs | Input for dry contact 5 Vdc, max 6 mA |
RS485 Digital Communication | Modbus server ASCII/RTU standard protocol |
Output 24 VDC for Digital Probe | Voltage 24 Vdc ±5%, max. 250 mA |
Short Circuit Protection | Self-resettable fuse |
Notes | Only instrument: 8W; instrument + 1 digital probe: 10.5W; instrument + 2 digital probes: 13.5W |