50 Series F/L

OPEN CHANNEL FLOW METER WITH ULTRASONIC/PIEZOMETRIC/RADAR LEVEL SENSOR

FEATURES

TYPES OF PDM (Primary Measurement Device)

Restrictions:

Restrictions:

Other:

Programming exponent or table with 30 points

TECHNICAL SPECIFICATION

Feature DESCRIPTION
Unit of Measure Flow rate: mc/h, lt/sec - cm, mm - Temperature: °C
Measurement Range 0...99999 mc/h - Up to 3 decimal points
Two Totalisers Absolute 9-digit (saved on Flash PROM non-resettable)
Partial 9-digit resettable
Display Graphic TFT colour LCD 480x272 (Visible Area 95x93)
Simultaneous display of: instantaneous flow rate (numeric & bar-graph), totalized volume, temperature, status of digital outputs, alarm events.
In scrolling: Status level of the analogue outputs, resettable totalizer
Checks 5 Keys
Data Logger Internal 32 Mbit 128000 record
Serial Output One RS485 galvanically separated modbus RTU
Analogue Outputs Two galvanically programmable separated
Relay Outputs Four for thresholds
Two for alarm (max load 1A at 230Vac resistive)
Power Supply 100...240Vac / dc 50-60Hz (Optional 24Vac / dc)
Isolation 4kV
Average Absorption <7W
Dimensions / Weight (LxHxD) 144x144x122.5 mm - Weight: 1 kg