S 103 C Flow Meter

CH2300 MEASURING TUBE U0-D0 INSTALLATION

FEATURES

APPLICATIONS

CH2300 INSTALLATION

SELECTION TABLE

ACCURACY DIAGRAM

The maximum permissible error is within
the limits shown in the following graph:

CH2300 FLOW RATES TABLE

Sensor DIAMATEr Flow [m³/h] RATIO Q3/Q1
Min. Q1 Trans. Q2 Q0.4% Perm. Q3 Overl. Q4
DN 50 - 2” 0.125 0.20 3.50 25.00 31.25 200
DN 65 - 2½” 0.2 0.32 6.00 40.00 50.00 200
DN 80 - 3” 0.315 0.50 9.00 63.00 78.75 200
DN 100 - 4” 0.50 0.80 14.00 100.00 125.00 200
DN 125 - 5” 0.80 1.28 22.00 160.00 200.00 200
DN 150 - 6” 1.25 2.00 32.00 250.00 312.50 200
DN 200 - 8” 3.15 5.04 57.00 630.00 787.50 200
DN 250 - 10” 5.0 8.00 90.00 1000.00 1250.00 200
DN 300 - 12” 8.0 12.50 128.00 1000.00 1250.00 125

TECHNICAL SPECIFICATION

SPECIFICATIOn DETAILS
Flow tube material AISI 304, SS316 (optional)
Flanges material Carbon steel, AISI 304, SS316 optional
Available electrodes SS 316L (standard), Hastelloy C, Hastelloy B, Titanium, Tantalum, Platinum
Internal lining Ebanite
Liquid temperature Up to 80°C
Standard flanged connections EN1092-1 PN 16, ANSI 150 on request
Installation requirements/conditions U0-D0
Protection degree IP68 permanent submersion at 1.5 m (EN 60529)