SP5 A
Thermostat-controlled self-emptying stationary sampler in stainless-steel cabinet
TECHNICAL SPECIFICATION
Feature | Description |
---|---|
Housing | Two separate SS 1.4301 compartments, each with door and lock |
Upper Part |
Control unit and dosing unit, with door and window. Upper canopy made of plastic material (Styrosun) can be opened for inspection and maintenance. |
Lower Part |
Distribution system and bottles for collecting the samples with blind door. Double wall insulation, thermostat controlled. |
Dimensions |
2x10L, 4x5L, 12x1.6L: 1290 mm (1930 mm with opened top) x 690 mm x 645 mm 24x2L: 1400 mm (2175 mm with opened top) x 800 mm x 850 mm |
Weight | 115 kg version with 2 bottles; greater for versions with more bottles |
Operating Temperature |
Ambient: -20...40°C Sample: 0...43°C |
Power Supply | 230V...50/60Hz; Consumption 350VA |
Bottle Variants |
Plastic: 2x10L Glass: 4x5L; 12x1.6L; 16x2L; 24x2L (other on request) |