At a pyrolysis plant, a tank-to-tank transfer skid works best as a shared transfer station: a manifold selecting source and destination tanks, a suction strainer and filter, a suitable pump, a meter, and where needed a sampling point and line heating. The pump is not the center of the design. What matters is which tank and layer the oil is drawn from, how much it is heated in transit, and how the meter reading is reconciled with level changes in both tanks.
Truck unloading and loading have their own pages; this one follows the oil inside the plant, from collection tank to dispatch tank.
Which tanks does pyrolysis oil pass through?
Layouts vary, but the oil usually passes several duty tanks, so define the skid's duty list first:
· Collection to settling tank: Raw product from the condensers goes to a tank where water and solids can separate.
· Settling tank to intermediate storage: The usable oil is drawn off, leaving separated water and bottom sediment behind.
· Blending between tanks: Oil from different production periods is combined in controlled proportions to even out shipping quality.
· Feeding the dispatch tank: An analyzed quality lot is moved to the final tank ahead of truck loading or process feed.
· Bottom water and sludge removal: Separated aqueous phase and sediment are removed through a separate line or container without entering the product line.
Draw-off point: which layer of the tank you are pumping
Pyrolysis oil does not always stay homogeneous in the tank. Biomass oils are usually single-phase, but for forest-residue oils a low-polarity top phase of 5–20 wt% can form depending on feedstock and process, and with aging an aqueous phase can separate once total water exceeds about 30 wt%. Solids also agglomerate into a bottom sludge layer during storage. For tire- and plastic-derived oils, layering behavior has to be established from the product's own analysis.
The skid suction should therefore select the tank nozzle explicitly: product is drawn from above the sludge, while bottom water and sediment leave through a separate connection. The open nozzle should be visible in the control system, with permissive logic that blocks a wrong-layer draw. Density logged at the meter is a practical sign that the layer being pumped is not the expected one.
Circulation and heating: heavy fuel oil habits do not carry over
Heavy fuel oil tanks are commonly kept hot and circulated continuously. For biomass pyrolysis oil, VTT recommends a different approach: indirect heating with a low surface temperature, preheating in the line close to the point of use, and no return of heated oil to the tank without cooling. Prolonged circulation with thermal cycling is reported to degrade quality significantly and raise viscosity; 40–80 °C is recommended for pumping. At 100 °C or more the oil reacts rapidly and can form solid residue.
For the skid, this means time-limited circulation, cooling after any loop heater before oil re-enters the tank, and skid heating held to what pumpability requires. These values apply to biomass oil; for tire and plastic oils the limit comes from stability testing. Heating methods are covered on the heated transfer page for pyrolysis oil.
Filtration, pumps and wetted parts
Solids can erode pumps and nozzles, so the handling chain must not block or fill with particles. In practice: a cleanable suction strainer ahead of the pump, a replaceable filter ahead of the meter, and differential pressure monitoring on the filter. If transfers cannot stop for cleaning, consider a duplex filter with a changeover valve.
Viscosity drives pump selection. Biomass pyrolysis oil is reported at 15–35 cSt at 40 °C, while tire and plastic oils vary by product. Centrifugal pump performance in liquids more viscous than water has to be corrected, and positive displacement pumps are often considered at higher viscosity and lower flow. Net positive suction head available should be checked against the pump requirement, remembering that suction pressure falls as the source tank level drops.
The low pH of biomass oil rules out carbon steel in pumps and lines. All wetted parts should be stainless steel or better, and every gasket and instrument has to be checked for compatibility. For vibrating-tube meters, material suitability cannot simply be inferred from the piping alloy and should be assessed against the meter supplier's corrosion data.
When different products share the skid
Biomass pyrolysis oil is not miscible with petroleum oils. If one skid also handles fuel oil or diesel, line residue can remain as a separate phase in the next transfer. Either dedicate the skid to one product or define a line-clearing and cleaning procedure. Alcohols such as methanol, ethanol and isopropanol dissolve bio-oil except for solids, but seal compatibility and flammability must be assessed.
Reconciling meter readings with tank levels
In-plant transfer meters are often process instruments, yet their readings should still agree with the level drop in the source and the rise in the destination. Terminal hydrocarbon management guidance separates apparent loss from measurement and accounting errors from real physical loss. For pyrolysis oil, the main sources of mismatch are:
Source of mismatch | Why it happens | How to reduce it |
Bottom water and sludge draining | Source tank level falls but the material never reaches the destination | Measure the drain separately or book it as a separate entry |
Level in a layered liquid | Phase boundaries and foam blur the surface the level gauge reads | Choose the gauging principle for the product and track interface level if needed |
Temperature and density differences | Average tank temperature differs from line temperature | Reconcile on mass, or account for temperature on both sides |
Line fill status | A line empty at the start and full at the end holds product | Record line status before and after each transfer |
Circulation path | Oil passing the meter and returning to the source can be counted as a transfer | Separate circulation and transfer routes by valve position |

Valve line-up and safety interlocks
In a multi-tank manifold, the most common error is a line-up that sends product to the wrong tank. Before a transfer starts, valve positions and free capacity in the destination are confirmed, and a high-level alarm plus independent overfill protection must be able to stop the pump. Low level in the source tank is interlocked to prevent dry running and sludge pickup. Storage-tank overfill protection guidance is a reference for these interlocks; which levels are protected, and how, follows the plant risk assessment.
TLY Energy's role
Depending on project scope, TLY Energy contributes engineering for selecting and supplying pumps, valves, filters and metering equipment for tank-to-tank transfer, configuring valve line-ups and level interlocks in the PLC and SCADA system, site installation, testing and commissioning, and maintenance and technical support. Responsibility for tank and pipework construction and for skid fabrication is agreed separately for each project.
What to prepare for a review
· Tank list with the duty of each tank, nozzle elevations and whether mixers are fitted
· Transfer scenarios: from which tank to which, expected quantity and duration
· Product analyses: viscosity versus temperature, water, solids, acidity, density
· Existing heating infrastructure and maximum allowable product temperature
· Level instruments and overfill protection arrangement
· Whether other products will pass through the same skid
Related pages
· Pyrolysis oil truck unloading systems: Receiving the product and moving it into the first tank.
· Heated transfer systems for pyrolysis oil: Choosing the heating method and the upper temperature limit.
· Batch metering systems for pyrolysis oil: Tracking quality lots formed in tanks with records and samples.
· Pyrolysis oil metering skids: Technology choice for the meter on the transfer line.
Tank-to-tank transfer FAQ
Can a tank be circulated continuously to keep it homogeneous?
For biomass pyrolysis oil this is not recommended. Prolonged circulation with thermal cycling is reported to degrade quality and increase viscosity, and returning heated oil to the tank without cooling is advised against. If homogenization is needed, keep it time-limited and avoid heating in the return line. For tire- and plastic-derived oils, the decision follows the product's stability testing.
Why do the meter and the tank gauges show different quantities?
The usual causes are separate draining of bottom water and sludge, a level gauge reading the wrong surface in a layered liquid, different temperatures in the tank and the line, and a line that is empty at the start and full at the end. Reconciling on mass and recording line status make the difference much easier to explain.
Can the same skid also transfer fuel oil?
Possibly, but biomass pyrolysis oil does not mix with petroleum oils, so line residue can stay as a separate phase in the next transfer. Lines must be cleared and flushed with a suitable liquid at each product change, and where products change often a dedicated skid is usually more reliable.
Which pump type suits a transfer skid?
It depends on the viscosity range, solids content and flow rate. Centrifugal pumps may be adequate for low-viscosity, clean product, while positive displacement pumps are often considered for high or variable viscosity. In every case, wetted parts must withstand an acidic product and suitable straining for solids must be installed ahead of the pump.
Should bottom water be drained through the transfer skid?
A separate drain line is preferred. If bottom water and sludge pass through the product line, they load the filters, foul the meter and distort the transfer record. Even where the same pump is used, a separate routing and a separate record of the drained quantity should be defined.